522 research outputs found
Recommended from our members
Entropy based adaptive particle filter
We propose a particle filter for the estimation of a partially observed Markov chain that has a non dynamic component. Such systems arise when we include unknown parameters or when we decompose non ergodic systems to their ergodic classes. Our main assumption is that the value of the non dynamic component determines the limiting distribution of the observation process. In such cases, we do not want to resample the particles that correspond to the non dynamic component of the Markov chain. Instead, we take a weighted average of particle filters corresponding to different values of the non dynamic component. The computation of the weights is based on entropy and the number of particles corresponding to each particle filter is proportional to the weights
MicroSUCI: A microsurgical background that incorporates suction under continuous irrigation
The microsurgical anastomosis is integral to the success of autologous-free tissue transfer. Successful performance of this procedure relies strongly on operator dexterity, which can be made more challenging when blood and edematous fluids obscure the field of view. Workflow is impeded by intermittent irrigation and suctioning, necessitating presence of an assistant, with risk of arterial thrombosis, from vessels being drawn into suction drains. To negate these current disadvantages and minimize the barrier of entry to microvascular operations, we designed, manufactured, and patented a novel three-dimensional printed microsurgical background device with microfluidic capabilities that allow continuous suction and irrigation as well as provide platforms that enable multiangle retraction to facilitate operator autonomy. This was validated in an ex vivo model, with the device found to be superior to the current standard. We believe that this will have major applicability to the improvement of microsurgeon
On Robustness of Discrete Time Optimal Filters
A new result on stability of an optimal nonlinear filter for a Markov chain with respect to small perturbations on every step is established. An exponential recurrence of the signal is assumed
Analogue micropower FET techniques review
A detailed introduction to published analogue circuit design techniques using Si and Si/SiGe FET devices for very low-power applications is presented in this review. The topics discussed include sub-threshold operation in FET devices, micro-current mirrors and cascode techniques, voltage level-shifting and class-AB operation, the bulk-drive approach, the floating-gate method, micropower transconductance-capacitance and log-domain filters and strained-channel FET technologies
A Conserved DNA Repeat Promotes Selection of a Diverse Repertoire of Trypanosoma brucei Surface Antigens from the Genomic Archive.
African trypanosomes are mammalian pathogens that must regularly change their protein coat to survive in the host bloodstream. Chronic trypanosome infections are potentiated by their ability to access a deep genomic repertoire of Variant Surface Glycoprotein (VSG) genes and switch from the expression of one VSG to another. Switching VSG expression is largely based in DNA recombination events that result in chromosome translocations between an acceptor site, which houses the actively transcribed VSG, and a donor gene, drawn from an archive of more than 2,000 silent VSGs. One element implicated in these duplicative gene conversion events is a DNA repeat of approximately 70 bp that is found in long regions within each BES and short iterations proximal to VSGs within the silent archive. Early observations showing that 70-bp repeats can be recombination boundaries during VSG switching led to the prediction that VSG-proximal 70-bp repeats provide recombinatorial homology. Yet, this long held assumption had not been tested and no specific function for the conserved 70-bp repeats had been demonstrated. In the present study, the 70-bp repeats were genetically manipulated under conditions that induce gene conversion. In this manner, we demonstrated that 70-bp repeats promote access to archival VSGs. Synthetic repeat DNA sequences were then employed to identify the length, sequence, and directionality of repeat regions required for this activity. In addition, manipulation of the 70-bp repeats allowed us to observe a link between VSG switching and the cell cycle that had not been appreciated. Together these data provide definitive support for the long-standing hypothesis that 70-bp repeats provide recombinatorial homology during switching. Yet, the fact that silent archival VSGs are selected under these conditions suggests the 70-bp repeats also direct DNA pairing and recombination machinery away from the closest homologs (silent BESs) and toward the rest of the archive
Control and ultrasonic actuation of a gas-liquid interface in a microfluidic chip
This article describes the design and manufacturing of a microfluidic chip,
allowing for the actuation of a gas-liquid interface and of the neighboring
fluid. A first way to control the interface motion is to apply a pressure
difference across it. In this case, the efficiency of three different
micro-geometries at anchoring the interface is compared. Also, the critical
pressures needed to move the interface are measured and compared to theoretical
result. A second way to control the interface motion is by ultrasonic
excitation. When the excitation is weak, the interface exhibits traveling
waves, which follow a dispersion equation. At stronger ultrasonic levels,
standing waves appear on the interface, with frequencies that are half integer
multiple of the excitation frequency. An associated microstreaming flow field
observed in the vicinity of the interface is characterized. The meniscus and
associated streaming flow have the potential to transport particles and mix
reagents
- …